What is the difference between DALI 1 and DALI-2?
Everyone in the field of LED lighting knows that DALI system is the most advanced lighting control system in the world at present. The principle of DALI system (What is DALI control system?-helvar ) is probably based on multiple intelligent modules connected to DALI bus.
DALI bus signal can be used to communicate with each intelligent module and transmit instructions and state information. It can not only control each lamp individually, such as linear control of brightness, color temperature, and color but also control the lamps in groups and set different scene modes and plans.
Dali-2 refers to the latest version of the DALI protocol, which has many new commands and features compared to the DALI system. The DALI system version only includes control devices, while Dali-2 includes control devices such as application controllers and input devices (such as sensors), as well as bus power supplies. Dali-2 updates on the original version of DALI (also known as DALI V-1) include:
A. Fix DALI's original version of the system for errors and deficiencies, for example, stricter timing requirements for transfers, and remove some of the features that were less used.
B. Added some new command interface and transmission message frame features. The control system is more standardized, forming IEC 62386-103 and IEC 62386-3XX series standards.
C. Mandatory authentication requirements. Compulsory certification is required for products that comply with DALI's latest standard, Dali-2.
In order to provide a better customer experience, we designed a new version of Dali2 + Push Function based on the EXISTING LED driver of the Dali system. For example HZD024ADI - DA.
n Features
l Constant current design, support DALI and Push dimming
l Wide input voltage range, high power factor
l Small and compact Size
l Protection: over-voltage/short circuit /overload
l No load power consumption<0.5W@220Vac
l Dimming depth 1%-100%
l Low cost, high reliability, isolated design, No flicker
l 3 years warranty
n Specifications and models
MODEL | HZD024ADI-DA | |||
OUTPUT | DC VOLTAGE | 6-36V | 6-36V | |
RATED CURRENT | 450MA | 600MA | ||
FLOATING VOLTAGE | 45V | 45V | ||
ACCURACY OF CURRENT | ±5% | |||
HOLD UPTIME | 500ms&220Vac at full load | |||
INPUT | VOLTAGE RANGE &FREQUENCY RANGE | 90-265Vac 50-60Hz | ||
POWER FACTOR | >0.9&220Vac | |||
EFFICIENCY&220Vac | 86% | 86% | ||
ENVIRONMENT | WORKING TEMP AND HUMIDITY | -25~+60℃ 0~40% RH | ||
STORAGE TEMP ANG HUMIDITY | -40~+80℃ 10~60% RH | |||
SAFETY&EMC | SAFETY STANDARDS | EN61347-2-13:2014+A1:2017;EN61347-1:2015+A1:2021; EN IEC60598-1:2021; EN62493:2015 | ||
EMC STANDARDS | EN IEC 55015:2019+A11:2020 ; EN IEC61000-3-2:2019;EN 61000-3-3:2013+A1:2019 EN61547:2009 | |||
OTHERS | DIMENSION | 130*43*22mm (L*W*H) | ||
PACKING | 98g |
※Press dimming (primary side)
serial number | Function | Operation | Explain |
1 | The electric memory | power on | When the LED driver is powered on, it will restore the memory before the LED driver is powered off If the LED driver is turned off before power off, then power on it After the lamp is still turned off if the LED driver is powered off before 50% brightness, Automatically restores to 50% brightness ( after power-on Degree memory after the last dimming stability of the brightness, the brightness of the dimming process Do not do memory), after powering on the first long dimming direction for dimming. |
2 | Turn on / Off lights | Short press 50ms-600 ms | If the light is originally on, the light will be off after a short press; If the lamp is off originally, the light will turn on after a short press, and the illuminance at this time is the illumination before turning off the lamp (illumination memory function). |
3 | Dimming | Long press 1 s to 3 s | Hold down the reset switch for a long time, and the lamp will enter the dimming state. If it was dimming for the previous time, it will automatically turn to dim for the next time. After releasing the reset button, the dimming will stop and maintain the current illumination. Dimming range 1%-100%.The default value is On for the first power-on duration. If the power-on brightness is the maximum, the value is dimmed for the first duration. |
4 | Synchronize all lights | Long press 10 s | If all the lights connected to the same SwitchDIM system are switched on or their brightness is inconsistent, hold down for 10s to turn all the lights on with the same brightness (50%), and hold down the next time to dim the dimming direction. |
5 | Change the gradient time | Long press 20 s | The gradient time affects the dimming speed, and the smaller the gradient time, the faster the dimming speed. The default dimming gradient time is 3s. When you hold down for 20s, change the dimming gradient time to 6s, and output 100% brightness (when you hold down for 10s, all lights will be synchronized and turn on 50%). When the send button is pressed again for 20s, the gradient time is changed to 3S; If you do not release the button, keep the brightness at 100%. |
6 | Reset to factory Settingsbuy | Long press 10 s | Press for 10s four times, with an interval of no more than 2s. Restore the gradient time, switch state, brightness, control mode, etc., to factory Settings. |
l DALI signals support IEC62386-102 protocol instructions.